Z8 Encore!
®
Flash Microcontroller Development Kit
User Manual
24
UM014605-0208 Z8 Encore!® Evaluation Board
Table 8 through Table 13 list jumper information concerning the shunt
status, functions, and devices affected of selected jumpers.
J11 SocketModem Power
(3 V DC/5 V DC)
J12 RS-485_1_EN
J13 RS-485_2_EN
J14 RT_1
J15 RT_2
Table 8. J6.9–J6.11-Modem Enable/Disable
Shunt Status Function Device Affected
IN Modem connector (P2) is
disabled
UART1 cannot communicate through P2.
Ports D and F can be assigned to functions
other than UART1.
OUT Modem connector (P2) is
enabled
If the embedded SocketModem is not in the
socket, UART1 communicates through P2.
Table 9. J6.12–J6.14-Console Enable/Disable
Shunt
Status Function Device Affected
IN Console connector (P1) is disabled If J6.12–14 is IN and J10 is IN, Port A
(3-5) is assigned to IrDA; if J10 is
OUT Port A (3-5) is assigned to
UART0.
OUT Console connector (P1) is enabled None
Table 7. Configuration Headers and Jumpers (Continued)
Header Function
Related Headers,
Registers or Devices